![]() ![]() Fire watchers must check all the areas affected by the impairment, including the occupied areas, as well as the areas that are not occupied. If a life-threatening situation is discovered, the person conducting the fire watch must immediately contact emergency personnel, alert the inhabitants to the emergency and assist in their evacuate. The fire watch requires the patrol of all areas of the building to look for evidence of smoke, fire or abnormal conditions. The requirement to implement a fire watch is triggered by the amount of time that the system is impaired, regardless of the nature of the impairment. The question of how much of the fire protection system must be impaired to cause a fire watch is not addressed in the standards, but a fire watch should be implemented if a significant portion of the system cannot operate as intended. The Code covers pre planned impairments that occur when the system must be shut down for a period of time to allow for open flame operations, such as welding in an area with automatic fire detection systems, or to be disconnected for the purposes of testing and maintenance. Emergency impairments can include an interruption in the water supply to the system, frozen or rupturing pipes, equipment failure, and any impairments that are identified during inspections of the system. In cases where the fire alarm signaling system is not working, a fire watch may be needed. ![]() The requirements for how to respond to sprinkler in your fire protection system are contained in Chapter 15 of the LSC's LSC Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems. ![]() The entire hot work area will be included in the fire watch. 3504.2.2 is located in the United States. The hot work area has no fire dangers or exposure to fire. The fire code official is authorized to extend the fire watch based on the work being done. A fire watch will be provided during hot work activities and will last for 30 minutes after the work is over. There is only one exception when there are no fire dangers or materials that can cause fires.ģ504.2.1 is required when necessary. Fire watches are required for any hot work activity and for at least 30 minutes after the work is done to reduce the potential for large fire losses. The National Fire Protection Association reports that between 20, the US fire departments responded to an average of 4, 630 fires in which 15 people died and $355 million in property damage was lost. Fire watches are a requirement for most property owners, which is a good thing. If fire protection systems are out of service for more than 4 hours in a day, many AHJs require fire watches, building evacuates, or ready firefighters. The condition and features of other fire protection systems, as well as the duration of the impairment, are also weighed by the AHJs. The National Fire Alarm and Signaling Code requires that if the fire alarm system is out for more than eight hours, the AHJs must be informed. When a fire protection system is undergoing quick repairs or revisions, it is important that the execution of one is straightforward. Fire Watches: A Requirement for Property Ownershipįire watches can be overwhelming for many property owners and can be expensive, given the diversion of manpower or hiring of outside contractors to keep a watch on the building. ![]()
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |